HomeAbout UsProductsContact UsFeed Back
   

PFC Series

 

GZM U25S

 

Please download the pdf

 

 

PD 25S


Features:

  • Universal AC input/ Full range
  • High Efficiency, and High reliability
  • Output protections: SCP/OVP/OPP/OLP
  • Wide operating ambient temperature (-20℃~70℃)
  • All using 105℃ long life electrolytic capacitors
  • 100% full load burn-in test
  • 2 years warranty

Specifications:

Model
PD-25-S3.3
PD-25-S5
PD-25-S12
PD-25-S15
PD-25-S24
Output
DC Output
3.3V
5V
12V
15V
24V
Rated Current
6A
5A
2.1A
1.7 A
1.1A
Current Range Note 2
0-6A
0-5A
0-2.1A
0-1.7A
0-1.1A
Ripple and Noise Note 2
0~70℃
80mV
80mV
120mV
120mV
120mV
-20~0℃
80mV
80mV
120mV
120mV
240mV
Voltage ADJ.  Range
±10% of rated output voltage
Voltage Accuracy
±2.0%
±2.0%
±1.0%
±1.0%
±1.0%
Line Regulation
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
Load Regulation
± 2.0%
± 2.0%
±1.0%
±1.0%
±1.0%
Set-up Time
<2.0S (120Vac input, Full load); <1.0S (230Vac input, Full load)
Hold up Time
>14mS(120Vac input, Full load); >30mS(230Vac input, Full load)
Temperature Coefficient
  ±0.03%/℃
Overshoot and Undershoot
  <5.0%
Input
Voltage Range  
  88Vac~264Vac
Frequency Range
  47Hz~63Hz
Efficiency ( Typical)
70%-120
75%-120
80%-120
81%-120
83%-120

71%-230

77%-230

82%-230

83%-230

84%-230

AC Current (max.)
1.60A

1.60A

1.50A
1.50A
1.50A
Inrush Current (Typical)
  30A@120Vac; 50A@230Vac Cold start
Leakage Current
  <3.5mA
Protection
Over Power
  105%~150% of rated output current, Constant power
Over Current
  105%~150% of rated output current, Constant current
Over Voltage
  105%~150% of rated output voltage, Constant Voltage
Shorted Circuit
  Long-term mode, auto recovery
Environment
Operating amb. Temp. & Hum.
  -20℃~70℃;  20%~90%RH  No condensing
Storage Temp. & Hum.
  -40℃~85℃;  10%~95%RH  No condensing
Safety & EMC (Node-3)
Safety Standards
  GB4943-2001; EN60950-1:2006
Withstand Voltage
  Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA.
  Secondary-PG:0.5KVDC;≤10mA
Isolation Resistance
  ≥100M ohms
Harmonic Current
  Compliance to EN61000-3-2,-3
EMS Immunity
  Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,
  light industry level,criteriaA
EMI Conduction&Radiation
  Compliance to EN55022(CISPR22) ClassB
Others
MTBF (MIL-HDBK-217F)
  More than 100,000Hrs (25℃, Full load)
Dimension  (L*W*H)
  93×51×28mm
Packing
  48PCS/CTN,G.W:10.4kgs
Cooling method
  Cooling by free air convection

 

Please download the pdf

 

 

PD 60


Features:

  • Universal AC input/ Full range
  • High Efficiency, and High reliability
  • Output protections: SCP/OVP/OPP/OLP
  •  Wide operating ambient temperature (-10℃~70℃)
  • All using 105℃ long life electrolytic capacitors
  • 100% full load burn-in test
  • 2 years warranty

Specifications:

Model
PD-60-5
PD-60-12
PD-60-15
PD-60-24
PD-60-28
PD-60-48
Output
DC Output
5V
12V
15V
24V
28V
485V
Rated Current
10A
5A
4A
2.5 A
2.15A
1.25A
Current Range Note 2
0~10A
0-5A
0~4A
0-2.5A
0-2.15A
0~1.25A
Ripple and Noise Note 3
50mV
120mV
120mV
120mV
120mV
240mV
Voltage ADJ.  Range
  ± 5% of rated output voltage
Voltage Accuracy
  ± 2.0%
Line Regulation
  ± 0.5%
Load Regulation
  ± 2.0%
Set-up Time
  <=2.0S (120Vac input, Full load); <=1.0S (230Vac input, Full load)
Hold up Time
  >=10mS(120Vac input, Full load); >=20mS(230Vac input, Full load)
Temperature Coefficient
  ± 0.03% /℃
Overshoot and Undershoot
  <5.0%
Input
Voltage Range  
  90Vac~264Vac
Frequency Range
  47Hz~63Hz
Efficiency ( Typical)
74%
79%
80%
80%
80%
83%
AC Current (max.)
1.60A

1.60A

1.50A
1.50A
1.50A
1.45A
Inrush Current (Typical)
  30A@120Vac; 50A@230Vac Cold start
Leakage Current
  <3.5mA
Protection
Over Current
  105%~150% of rated output current
Over Voltage
  110%~140% of rated output voltage
Shorted Circuit
  Long-term mode, auto recovery
Environment
Operating amb. Temp. & Hum.
  -1℃~7℃; 20%~90% RH No condensing
Storage Temp. & Hum.
  -4℃~8℃; 10%~95% RH No condensing
Safety & EMC (Node-3)
Safety Standards
  UL60950-1
Withstand Voltage
  Primary-Secondary:3.0KVac; Primary-PG:1.5KVac; Secondary-PG:0.5KVDC
Isolation Resistance
  100M ohms
EMC Standards
  EN55022 Class B;EN-61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN61000-6-2
Others
MTBF (MIL-HDBK-217F)
  100, 000Hrs (25 , Full load)℃
Dimension  (L*W*H)
  129× 98×38mm
Packing
  7P/8.255mm terminal block
Cooling method
  Cooling by free air convection

 

Please download the pdf

 

 

PD 100


Features:

  • Universal AC input/ Full range
  • High Efficiency, and High reliability
  • Output protections: SCP/OVP/OPP/OLP
  • Wide operating ambient temperature (-20℃~70℃)
  • All using 105℃ long life electrolytic capacitors
  • 100% full load burn-in test
  • 2 years warranty

Specifications:

Model
 
PD-100-5
PD-100-12
PD-100-15
PD-100-24
PD-100-48
Output
DC Output
5V
12V
15V
24V
48V
Rated Current
16A
8.5A
7A
4.5 A
2.3A
Current Range Note 2
0~16A
0~8.5A
0~7A
0-4.5A
0-2.3A
Ripple and Noise Note 3
0~70℃
80mV
100mV
100mV
120mV
200mV
-20~0℃
120mV
120mV
120mV
120mV
200mV
Voltage ADJ. Range
4.2V-6.0   10.4V-13.6V 13.0V-17.0V 21.0V-28.0V 43.0V-54.0V
Voltage Accuracy
±2.0%
±1 .0%
± 1.0%
± 1.0%
± 1.0%
Line Regulation
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
Load Regulation
± 1.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
Set-up Time
  <2.0S (120Vac input, Full load); <1.0S (230Vac input, Full load)
Hold up Time
  >10mS(120Vac input, Full load); >20mS(230Vac input, Full load)
Temperature Coefficient
  ± 0.03% /℃
Overshoot and Undershoot
  <5.0%
Input
Voltage Range
  90Vac~264Vac
Frequency Range
  47Hz~63Hz
Efficiency ( Typical)
78%-120
79%-120
81%-120
84%-120
83%-120
79%-120
81%-230
83%-230
85%-230
84%-230
AC Current (max.)
2.0A
2.5A
2.5A
2.4A
2.5A
Inrush Current (Typical)
  20A@120Vac,40A@230Vac      Cold start
Leakage Current
  <0.4Ma@120Vac     <0.75mA@230Vac
Protection
Over Power   105%~150% of rated output current, Constant power, auto recovery
Over Current
  105%~150% of rated output current, Constant power, auto recovery
Over Voltage
  110%~140% of rated output voltage, auto recovery
Shorted Circuit
  Long-term mode, auto recovery
Environment
Operating amb. Temp. & Hum.
  -20℃~70℃;  20%~90%RH  No condensing
Storage Temp. & Hum.
  -20℃~85℃;  10%~95%RH  No condensing
Safety & EMC Note4
Safety Standards
  GB4943-2001; EN60950-1:2006
Withstand Voltage
  Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA.
  Secondary-PG:0.5KVDC;≤10mA.
Isolation Resistance
  ≥100M ohms
EMI Conduction&Radiation
  Compliance to EN55022(CISPR22)ClassB
Harmonic Current
  Compliance to EN61000-3-2,-3
EMS Immunity
  Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,
  light industry level,criteriaA
Others
MTBF (MIL-HDBK-217F)
  More than 100, 000Hrs (25 , Full load)℃
Dimension (L*W*H)
  160×98×38mm
Connection
  20PCS/CTN, G.W :13.6kgs
Cooling method
  Cooling by free air convection

 

Please download the pdf

 

 

PD 150


Features:

  • 115/230VAC by Switch
  • High Efficiency, and High reliability
  • Output protections: SCP/OVP/OPP/OLP
  • Wide operating ambient temperature (-20℃~70℃)
  • All using 105℃ long life electrolytic capacitors.
  • 100% full load burn-in test
  •  2 years warranty

Specifications:

Model
 
PD-150-3.3
PD-150-5
PD-150-12
PD-150-15
PD-150-24
PD-150-48
Output
DC Output
3.3V
5V
12V
15V
24V
48V
Rated Current
30A
26A
12.5A
10A
6.5A
3.3A
Current Range Note 2
0~30A
0~26A
0~12.5A
0~10A
0~6.5A
0~3.3A
Ripple and Noise Note 3
80mV
80mV
120mV
120mV
120mV
200mV
Voltage ADJ. Range
  ± 10% of rated output voltage
Voltage Accuracy
± 3%
± 2.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
Line Regulation
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
Load Regulation
± 3.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
Set-up Time
  <=2.0S (120Vac input, Full load); <=1.0S (230Vac input, Full load)
Hold up Time
  >=10mS(120Vac input, Full load); >=20mS(230Vac input, Full load)
Temperature Coefficient
  ± 0.03% /℃
Overshoot and Undershoot
  <5.0%
Input
Voltage Range
  88Vac~132Vac/176Vac~264Vac
Frequency Range
  47Hz~63Hz
Efficiency ( Typical)
115Vac
73%
78%
83%
83%
84%
85%
230Vac
74%
79%
83%
84%
85%
86%
AC Current (max.)
3.5A
3.5A
4.0A
4.0A
4.0A
4.0A
Inrush Current (Typical)
  20A@120Vac; 40A@230Vac Cold start
Leakage Current
  <3.5mA
Protection
Over Current
  105%~150% of rated output current,auto recovery
Over Voltage
  120%~150% of rated output voltage,auto recovery
Shorted Circuit
  Long-term mode, auto recovery
Environment
Operating amb. Temp. & Hum.
  -2℃~70 ; 20% ~90% RH No condensing(refer to the derating curve)℃
Storage Temp. & Hum.
  -40 ~85 ; 10% ~95% RH No condensing℃ ℃
Safety & EMC Note4
Safety Standards
  UL60950-1
Withstand Voltage
  Primary-Secondary:3.0KVac; Primary-PG:1.5KVac; Secondary-PG:0.5KVDC
Isolation Resistance
  100M ohms
EMC standards
  EN55022 Class B;EN-61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN61000-6-2
Others
MTBF (MIL-HDBK-217F)
  More than 100, 000Hrs (25 , Full load)℃
Dimension (L*W*H)
  198× 98× 38mm
Connection
  7P/8.025mm barrier terminal block
Cooling method
  Cooling by free air convection
Note

1. All parameters NOT specially mentioned are measured at rated input, rated load and 25 of ambient temperature.℃2. De-rating according to operating ambient temperature and input AC voltage, Please check the de-rating curve for more details information. 3. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 4. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.

 