PD-150


Features:

  • 115/230VAC by Switch
  • High Efficiency, and High reliability
  • Output protections: SCP/OVP/OPP/OLP
  • Wide operating ambient temperature (-20℃~70℃)
  • All using 105℃ long life electrolytic capacitors.
  • 100% full load burn-in test
  •  2 years warranty
 
Specification

 

Model
 
PD-150-3.3
PD-150-5
PD-150-12
PD-150-15
PD-150-24
PD-150-48
Output
DC Output
3.3V
5V
12V
15V
24V
48V
Rated Current
30A
26A
12.5A
10A
6.5A
3.3A
Current Range Note 2
0~30A
0~26A
0~12.5A
0~10A
0~6.5A
0~3.3A
Ripple and Noise Note 3
80mV
80mV
120mV
120mV
120mV
200mV
Voltage ADJ. Range
  ± 10% of rated output voltage
Voltage Accuracy
± 3%
± 2.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
Line Regulation
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
Load Regulation
± 3.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
Set-up Time
  <=2.0S (120Vac input, Full load); <=1.0S (230Vac input, Full load)
Hold up Time
  >=10mS(120Vac input, Full load); >=20mS(230Vac input, Full load)
Temperature Coefficient
  ± 0.03% /℃
Overshoot and Undershoot
  <5.0%
Input
Voltage Range
  88Vac~132Vac/176Vac~264Vac
Frequency Range
  47Hz~63Hz
Efficiency ( Typical)
115Vac
73%
78%
83%
83%
84%
85%
230Vac
74%
79%
83%
84%
85%
86%
AC Current (max.)
3.5A
3.5A
4.0A
4.0A
4.0A
4.0A
Inrush Current (Typical)
  20A@120Vac; 40A@230Vac Cold start
Leakage Current
  <3.5mA
Protection
Over Current
  105%~150% of rated output current,auto recovery
Over Voltage
  120%~150% of rated output voltage,auto recovery
Shorted Circuit
  Long-term mode, auto recovery
Environment
Operating amb. Temp. & Hum.
  -2℃~70 ; 20% ~90% RH No condensing(refer to the derating curve)℃
Storage Temp. & Hum.
  -40 ~85 ; 10% ~95% RH No condensing℃ ℃
Safety & EMC Note4
Safety Standards
  UL60950-1
Withstand Voltage
  Primary-Secondary:3.0KVac; Primary-PG:1.5KVac; Secondary-PG:0.5KVDC
Isolation Resistance
  100M ohms
EMC standards
  EN55022 Class B;EN-61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN61000-6-2
Others
MTBF (MIL-HDBK-217F)
  More than 100, 000Hrs (25 , Full load)℃
Dimension (L*W*H)
  198× 98× 38mm
Connection
  7P/8.025mm barrier terminal block
Cooling method
  Cooling by free air convection
Note

1. All parameters NOT specially mentioned are measured at rated input, rated load and 25 of ambient temperature.℃2. De-rating according to operating ambient temperature and input AC voltage, Please check the de-rating curve for more details information. 3. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 4. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.

 

Please download the pdf

 

 