HomeAbout UsProductsContact UsFeed Back
   

DIN RAIL SMPS Modules

 

Din Rail S.M.P.S. Modules-24V 1A


 


Features:

  • Single phase input
  • Built in transient protector & EMI filter
  • Protection against short circuit , overload & over voltage
  • Low ripple & noise
  • Cooling by free air convection
  • Power OK indication, terminations, output set control & rating details on front
  • 100% full load burn in test
  • Low cost
  • High reliability
  • Compact
  • DIN rail mountable.
 
Specification

 

AC Input Voltage Range: 90 - 130VAC & 180 - 270VAC
AC Input Current (MAX.) : 0.6A at 110VAC & 0.3A at 230VAC
AC Inrush Current: 16A at 110VAC & 32A at 230VAC
Input Frequency: 47 ~ 63 Hz
Efficiency: 70 ~75%
Isolation: Input - Output : 2KVAC , 1minute
Input - Earth : 2KVAC , 1minute
Output - Earth : 0.5KVAC , 1minute
Overload Protection: 105% ~ 130% of full load
Line & Load Regulation: Better than 0.5%
Hold Up Time: >20ms
Operating Ambient: 0°C ~ 50°C, 95% RH
Storage Temperature: -20°C ~ 85°C
Weight: 240 grams
Mounting: 35mm DIN rail

 

Order Code
Output
Ripple & noise
Over voltage

Protection

I/P: 230VAC
I/P: 110VAC
G31-24-05
G32-24-05
5V:2.5A
< 100mV
< 7V
G31-24-09
G32-24-09
9V:2.5A
< 100mV
< 12V
G31-24-12
G32-24-12
12V:2A
< 120mV
< 16V
G31-24-15
G32-24-15
15V:1.5A
< 150mV
< 20V
G31-24-24
G32-24-24
24V:1A
< 240mV
< 30V
G31-24-48
G32-24-48
48V:0.5A
< 350mV
< 63V
 

Din Rail S.M.P.S. Modules-24V 2.5A


 


Features:

  • Single phase input
  • Built in transient protector & EMI filter
  • Protection against short circuit , overload & over voltage
  • Low ripple & noise
  • Cooling by free air convection
  • Power OK indication, terminations, output set control & rating details on front
  • 100% full load burn in test
  • Low cost
  • High reliability
  • Compact
  • DIN rail mountable.
 
Specification

 

AC Input Voltage Range: 90 - 130VAC & 180 - 270VAC
AC Input Current (MAX.) : 2A at 110VAC & 1A at 230VAC
AC Inrush Current: 16A at 110VAC & 32A at 230VAC
Input Frequency: 47 ~ 63 Hz
Efficiency: 70 ~75%
Isolation: Input - Output : 3KVAC , 1minute
Input - Earth : 2KVAC , 1minute
Output - Earth : 0.5KVAC , 1minute
Overload Protection: 105% ~ 130% of full load
Line & Load Regulation: Better than 0.5%
Hold Up Time: >20ms
Operating Ambient: 0°C ~ 50°C, 95% RH
Storage Temperature: -20°C ~ 85°C
Weight: 400 grams
Mounting: 35mm DIN rail

 

Order Code
Output
Ripple & noise
Over voltage

Protection

I/P: 230VAC
I/P: 110VAC
G31-60-05
G32-60-05
5V:4A
< 100mV
< 7V
G31-60-12
G32-6012
12V:5A
< 120mV
< 16V
G31-60-15
G32-60-15
15V:4A
< 150mV
<20V
G31-60-24
G32-60-24
24V:2.5A
<240mV
<30V
G31-60-48
G32-60-48
48V:1.25A
< 350mV
<63V
 

Din Rail S.M.P.S. Modules-24V 5A


 


Features:

  • Single phase input
  • Built in transient protector & EMI filter
  • Protection against short circuit , overload & over voltage
  • Low ripple & noise
  • Cooling by free air convection
  • Power OK indication, terminations, output set control & rating details on front
  • 100% full load burn in test
  • Low cost
  • High reliability
  • Compact
  • DIN rail mountable.
 
Specification

 

AC Input Voltage Range: 90 - 130VAC & 180 - 270VAC
AC Input Current (MAX.) : 3A at 110VAC & 1.5A at 230VAC
AC Inrush Current: 16A at 110VAC & 32A at 230VAC
Input Frequency: 47 ~ 63 Hz
Efficiency: 70 ~75%
Isolation: Input - Output : 3KVAC , 1minute
Input - Earth : 2KVAC , 1minute
Output - Earth : 0.5KVAC , 1minute
Overload Protection: 105% ~ 130% of full load
Line & Load Regulation: Better than 0.5%
Hold Up Time: >20ms
Operating Ambient: 0°C ~ 50°C, 95% RH
Storage Temperature: -20°C ~ 85°C
Weight: 530 grams
Mounting: 35mm DIN rail

 

Order Code
Output
Ripple & noise
Over voltage

Protection

I/P: 230VAC
I/P: 110VAC
G31-120-12
G32-120-12
12V:8A
< 120mV
< 16V
G31-120-15
G32-120-15
15V:6A
< 150mV
<20V
G31-120-24
G32-120-24
24V:5A
<240mV
<30V
G31-120-48
G32-120-48
48V:2.5A
< 350mV
<63V
 

Din Rail S.M.P.S. Modules-24V 10A


 


Features:

  • Single phase input
  • Built in transient protector & EMI filter
  • Protection against short circuit , overload ,overtemperature & over voltage
  • Low ripple & noise
  • Forced cooling (Internal fan)
  • Power OK indication, terminations, output set control & rating details on front
  • 100% full load burn in test
  • Low cost
  • High reliability
  • Compact
  • DIN rail mountable.
 
Specification

 

AC Input Voltage Range: 90 - 130VAC & 180 - 270VAC
AC Input Current (MAX.) : 5A at 110VAC & 2.5A at 230VAC
AC Inrush Current: 16A at 110VAC & 32A at 230VAC
Input Frequency: 47 ~ 63 Hz
Efficiency: 70 ~75%
Isolation: Input - Output : 2KVAC , 1minute
Input - Earth : 2KVAC , 1minute
Output - Earth : 0.5KVAC , 1minute
Overload Protection: 105% ~ 130% of full load
Line & Load Regulation: Better than 0.5%
Hold Up Time: >20ms
Operating Ambient: 0°C ~ 50°C, 95% RH
Storage Temperature: -20°C ~ 85°C
Weight: 990 grams
Mounting: 35mm DIN rail

 

Order Code
Output
Ripple & noise
Over voltage

Protection

I/P: 230VAC
I/P: 110VAC
G31-250-12
G32-250-12
12V:20A
< 120mV
< 16V
G31-250-24
G32-250-24
24V:10A
<240mV
<30V
G31-250-48
G32-250-48
48V:5A
< 350mV
<63V
 

Din Rail S.M.P.S. Modules-24V 20A


 


Features:

  • Single phase input
  • Built in transient protector & EMI filter
  • Protection against short circuit , overload ,overtemperature & over voltage
  • Low ripple & noise
  • Forced cooling (Internal fan)
  • Power OK indication, terminations, output set control & rating details on front
  • 100% full load burn in test
  • Low cost
  • High reliability
  • Compact
  • DIN rail mountable.
 
Specification

 

AC Input Voltage Range: 90 - 130VAC & 180 - 270VAC
AC Input Current (MAX.) : 9A at 110VAC & 4.5A at 230VAC
AC Inrush Current: 16A at 110VAC & 32A at 230VAC
Input Frequency: 47 ~ 63 Hz
Efficiency: 70 ~75%
Isolation: Input - Output : 2KVAC , 1minute
Input - Earth : 2KVAC , 1minute
Output - Earth : 0.5KVAC , 1minute
Overload Protection: 105% ~ 130% of full load
Line & Load Regulation: Better than 0.5%
Hold Up Time: >20ms
Operating Ambient: 0°C ~ 50°C, 95% RH
Storage Temperature: -20°C ~ 85°C
Weight: 1450 grams
Mounting: 35mm DIN rail

 

Order Code
Output
Ripple & noise
Over voltage

Protection

I/P: 230VAC
I/P: 110VAC
G31-500-24
G32-500-24
24V:20A
<240mV
<30V
G31-500-48
G32-500-48
48V:10A
< 350mV
<63V
 

Din Rail S.M.P.S. Modules-Dual Output:70W

 


Features:

  • Single phase input
  • Built in transient protector & EMI filter
  • Protection against short circuit , overload & over voltage
  • Low ripple & noise
  • Cooling by free air convection
  • Power OK indication, terminations, output set control & rating details on front
  • 100% full load burn in test
  • Low cost
  • High reliability
  • Compact
  • DIN rail mountable.
 
Specification

 

AC Input Voltage Range: 90 - 130VAC & 180 - 270VAC
AC Input Current (MAX.) : 2A at 110VAC & 1A at 230VAC
AC Inrush Current: 16A at 110VAC & 32A at 230VAC
Input Frequency: 47 ~ 63 Hz
Efficiency: 70 ~75%
Isolation: Input - Output : 2KVAC , 1minute
Input - Earth : 2KVAC , 1minute
Output - Earth : 0.5KVAC , 1minute
Overload Protection: 105% ~ 130% of full load
Line & Load Regulation: Better than 0.5%
Hold Up Time: >20ms
Operating Ambient: 0°C ~ 50°C, 95% RH
Storage Temperature: -20°C ~ 85°C
Weight: 490 grams
Mounting: 35mm DIN rail

 

Order Code
Output
Ripple & noise
Over voltage

Protection

I/P: 230VAC
I/P: 110VAC
G31-70-05-05
G32-70-05-05
+5V : 6A
< 100mV
< 7V
-5V : 1.5A
< 100mV
G31-70-12-05
G32-70-12-05
12V : 4A
< 120mV
< 16V
5V : 1.5A
< 100mV
G31-70-12-12
G32-70-12-12
+12V : 4A
< 120mV
< 16V
-12V : 1.5A
< 120mV
G31-70-15-05
G32-70-15-05
+15V : 4A
< 150mV
< 20V
-5V : 1.5A
< 100mV
G31-70-15-15
G32-70-15-15
15V : 3A
< 240mV
< 20V
-15V : 1.5A
< 150mV
G31-70-24-05
G32-70-24-05
24V : 2A
<240mV
<30V
5V : 1.5A
< 100mV
G31-70-24-12
G32-70-24-12
24V : 2A
< 240mV
< 30V
12V : 1.5A
< 120mV
G31-70-24-15
G32-70-24-15
24V : 2A
< 240mV
< 30V
15V : 1.5A
< 150mV
 
 
Home | About Us | Products | Contact Us | Feedback