HomeAbout UsProductsContact UsFeed Back
   
 
 

BM-315U

 

Environmental

 

Operating Temperature : 0 - 50°C
Non-operating Temperature: 0 - 75°C
Humidity: 5% to 95% non-condensing

 

Safety & EMI

 

Safety: Designed to meet IEC - 1950
EMI: FCC Class - B / CISPR22

 

Protectins

 

Output Over Voltage: PSU Trips on over voltage condition
Output Over Load: output folds back on over load
Short Circuit: Goes to hick-up mode on short circuit
Battery Rev. Polarity: PSU protected throuh internal fuse

 

Indications

 

Mains On: When AC is available
Battery On: When Battery is supplying power to the Radio
Battery Low: When Battery voltage is less than 11.4V.

 

Specifications

 

AC Input Voltage range 170 - 270 V AC or 90 - 135 V AC with changeover switch - Optional
AC Input IEC 320 Socket
DC Output Voltage 11.0-14.0 V DC
DC Output Current - Equipment 30.0 Amps
DC Output Current - Battery * 10.0 Amps
Output Ripple ( P-P max ) ** < 1 %
Output Voltage regulation ± 3 %
Batt. deep discharge cut-off facility Available
Mattering: Optional
Dimensions ( W X H X D ) 190 x 75 x 160 (In mm)
Weight ( in Kg. ) 3.8
* Battery current when Radio is not in Transmit mode
** While measuring the Ripple & Noise, 10 µF Elec. Cap and 104 CD Cap to be connected across the output.
 
Home | About Us | Products | Contact Us | Feedback
© 2009 National Controlling Equipment industries.