Environmental

 

Operating Temperature : 0 - 50°C
Non-operating Temperature: 0 - 75°C
Humidity: 5% to 95% non-condensing

 

Safety & EMI

 

Safety: Designed to meet IEC - 1950
EMI: FCC Class - B / CISPR22

 

Protectins

 

Output Over Voltage: PSU Trips on over voltage condition
Output Over Load: output folds back on over load
Short Circuit: Gosto hick-up mode on short circuit
Battery Rev. Polarity: PSU protected throuh internal fuse

 

Indications

 

Mains On: When AC is available
Battery On: When Battery is supplying power to the Radio
Battery Low: When Battery voltage is less than 11.4V.

 

Output Specifications

 

AC Input Voltage range 170 - 270 V AC
AC Input 3 Pin 5.0 A Power cord
DC Output Voltage 13.5 V DC
DC Output Current - Equipment 10.0 Amps
DC Output Current - Battery * 5.0 Amps
Output Ripple ( P-P max ) ** < 1 %
Output Voltage regulation ± 3 %
Batt. deep discharge cut-off facility Optional
Dimensions ( W X H X D ) 190 X 75 X 160 ( In mm )
Weight ( in Kg. ) 1.9
* Battery current when Radio is not in Transmit mode
** While measuring the Ripple & Noise, 10 µF Elec. Cap and 104 CD Cap to be connected across the output.
 